FVXG25K2V1B / RXLG25K2V1B |
FVXG25K2V1B / RXLG25K3V1B |
FVXG35K2V1B / RXLG35K3V1B |
FVXG35K2V1B / RXLG35K2V1B |
FVXG50K2V1B / RXLG50K2V1B |
FVXG50K2V1B / RXLG50K3V1B |
Hladilna kapaciteta
|
Min.
|
kW
|
1.3
|
1.3
|
1.4
|
1.4
|
1.7
|
1.7
|
|
Maks.
|
kW
|
3.0
|
3.0
|
3.8
|
3.8
|
5.6
|
5.6
|
|
Nom.
|
kW
|
2.5 (3)
|
2.5 (2)
|
3.5 (2)
|
3.5 (3)
|
5.0 (2)
|
5.0 (2)
|
Priključki cevne napeljave
|
Tekočina
|
Zun. premer
|
mm
|
6.35
|
6.35
|
6.35
|
6.35
|
6.35
|
6.35
|
|
Plin
|
Zun. premer
|
mm
|
9.5
|
9.5
|
9.5
|
9.5
|
12.7
|
12.7
|
|
Izpust
|
OD
|
mm
|
|
18.0
|
18.0
|
|
18.0
|
18.0
|
Nazivna učinkovitost
|
Letna por.energ.
|
kWh
|
275
|
275
|
475
|
476
|
760
|
760
|
|
EER
|
|
4.55
|
4.55
|
3.68
|
3.68
|
3.29 (1)
|
3.29 (1)
|
|
COP
|
|
4.36
|
4.36
|
3.72
|
3.72
|
3.67 (1)
|
3.67 (1)
|
|
Direktiva o energijskih oznakah
|
Hlajenje
|
|
A
|
A
|
A
|
A
|
A
|
A
|
|
|
Ogrevanje
|
|
A
|
A
|
A
|
A
|
A
|
A
|
Grelna kapaciteta
|
Nom.
|
kW
|
3.4 (4)
|
3.4 (3)
|
4.5 (3)
|
4.5 (4)
|
5.8 (3)
|
5.8 (3)
|
|
Min.
|
kW
|
1.3
|
1.3
|
1.4
|
1.4
|
1.7
|
1.7
|
|
Maks.
|
kW
|
4.5
|
4.5
|
5.0
|
5.0
|
8.1
|
8.1
|
Opombe
|
(1) - Energijska oznaka: lestvica od A (najvišja učinkovitost) do G (najmanjša učinkovitost)
|
(1) - EER/COP v skladu z Eurovent 2012, za uporabo samo zunaj EU
|
(1) - EER/COP v skladu z Eurovent 2012, za uporabo samo zunaj EU
|
(1) - Energijska oznaka: lestvica od A (najvišja učinkovitost) do G (najmanjša učinkovitost)
|
(1) - EER/COP v skladu z Eurovent 2012, za uporabo samo zunaj EU
|
(1) - EER/COP v skladu z Eurovent 2012, za uporabo samo zunaj EU
|
|
(2) - Letna poraba energije: na podlagi povprečne rabe 500 obratovalnih ur na leto pri polni obremenitvi (nominalni pogoji)
|
(2) - Hlajenje: Notranja temperatura 27° CDB, 19,0° CWB; zunanja temperatura 35° CDB; 24° CWB; ekvivalentna dolžina cevi: 5 m (horizontalno)
|
(2) - Hlajenje: Notranja temperatura 27° CDB, 19,0° CWB; zunanja temperatura 35° CDB; 24° CWB; ekvivalentna dolžina cevi: 5 m (horizontalno)
|
(2) - Letna poraba energije: na podlagi povprečne rabe 500 obratovalnih ur na leto pri polni obremenitvi (nominalni pogoji)
|
(2) - Hlajenje: Notranja temperatura 27° CDB, 19,0° CWB; zunanja temperatura 35° CDB; 24° CWB; ekvivalentna dolžina cevi: 5m
|
(2) - Hlajenje: Notranja temperatura 27° CDB, 19,0° CWB; zunanja temperatura 35° CDB; 24° CWB; ekvivalentna dolžina cevi: 5m
|
|
(3) - Hlajenje: Notranja temperatura 27° CDB, 19,0° CWB; zunanja temperatura 35° CDB; 24° CWB; ekvivalentna dolžina cevi: 5 m (horizontalno)
|
(3) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB; ekvivalentna dolžina cevi hladilnega sredstva: 5 m (horizontalno)
|
(3) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB; ekvivalentna dolžina cevi hladilnega sredstva: 5 m (horizontalno)
|
(3) - Hlajenje: Notranja temperatura 27° CDB, 19,0° CWB; zunanja temperatura 35° CDB; 24° CWB; ekvivalentna dolžina cevi: 5 m (horizontalno)
|
(3) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB; ekvivalentna dolžina cevi hladilnega sredstva: 5m
|
(3) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB; ekvivalentna dolžina cevi hladilnega sredstva: 5m
|
|
(4) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB; ekvivalentna dolžina cevi hladilnega sredstva: 5 m (horizontalno)
|
(4) - 220V
|
(4) - 220V
|
(4) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB; ekvivalentna dolžina cevi hladilnega sredstva: 5 m (horizontalno)
|
(4) - 220V
|
(4) - 220V
|
|
(5) - Nom. učink.: hlajenje pri 35°/27° nom. obrem., gretje pri 7°/20° nom. obrem.
|
(5) - 230V
|
(5) - 230V
|
(5) - Nom. učink.: hlajenje pri 35°/27° nom. obrem., gretje pri 7°/20° nom. obrem.
|
(5) - 230V
|
(5) - 230V
|
|
|
(6) - 240V
|
(6) - 240V
|
|
(6) - 240V
|
(6) - 240V
|
|
|
(7) - Nom. učink.: hlajenje pri 35°/27° nom. obrem., gretje pri 7°/20° nom. obrem.
|
(7) - Nom. učink.: hlajenje pri 35°/27° nom. obrem., gretje pri 7°/20° nom. obrem.
|
|
(7) - Nom. učink.: hlajenje pri 35°/27° nom. obrem., gretje pri 7°/20° nom. obrem.
|
(7) - Nom. učink.: hlajenje pri 35°/27° nom. obrem., gretje pri 7°/20° nom. obrem.
|