| FVXG25K2V1B / RXG25K2V1B | FVXG25K2V1B / RXG25K3V1B | FVXG35K2V1B / RXG35K2V1B | FVXG35K2V1B / RXG35K3V1B | FVXG50K2V1B / RXG50K2V1B | FVXG50K2V1B / RXG50K3V1B | ||||
|---|---|---|---|---|---|---|---|---|---|
| Hladilna kapaciteta | Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | |
| Maks. | kW | 3.0 | 3.0 | 3.8 | 3.8 | 5.6 | 5.6 | ||
| Nom. | kW | 2.5 (3) | 2.5 (2) | 3.5 (3) | 3.5 (2) | 5.0 (3) | 5.0 (2) | ||
| Priključki cevne napeljave | Tekočina | Zun. premer | mm | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 | 6.35 |
| Gas | Zun. premer | mm | 9.5 | 9.5 | 9.5 | 9.5 | 12.7 | 12.7 | |
| Drain | OD | mm | 18 | 18 | 18 | 18 | 18 | 18 | |
| Nazivna učinkovitost | Letna por.energ. | kWh | 275 | 275 | 475 | 475 | 760 | 760 | |
| EER | 4.55 | 4.55 | 3.68 | 3.68 | 3.29 | 3.29 | |||
| COP | 4.36 | 4.36 | 3.72 | 3.72 | 3.67 | 3.67 | |||
| Direktiva o energijskih oznakah | Hlajenje | A | A | A | A | A | A | ||
| Ogrevanje | A | A | A | A | A | A | |||
| Grelna kapaciteta | Nom. | kW | 3.4 (4) | 3.4 (3) | 4.5 (4) | 4.5 (3) | 5.8 (4) | 5.8 (3) | |
| Min. | kW | 1.3 | 1.3 | 1.4 | 1.4 | 1.7 | 1.7 | ||
| Maks. | kW | 4.5 | 4.5 | 5.0 | 5.0 | 8.1 | 8.1 | ||
| Opombe | (1) - Energijska oznaka: lestvica od A (najvišja učinkovitost) do G (najmanjša učinkovitost) | (1) - EER/COP v skladu z Eurovent 2012, za uporabo samo zunaj EU | (1) - Energijska oznaka: lestvica od A (najvišja učinkovitost) do G (najmanjša učinkovitost) | (1) - EER/COP v skladu z Eurovent 2012, za uporabo samo zunaj EU | (1) - Energijska oznaka: lestvica od A (najvišja učinkovitost) do G (najmanjša učinkovitost) | (1) - EER/COP v skladu z Eurovent 2012, za uporabo samo zunaj EU | |||
| (2) - Letna poraba energije: na podlagi povprečne rabe 500 obratovalnih ur na leto pri polni obremenitvi (nominalni pogoji) | (2) - Hlajenje: notranja temp. 27°CDB, 19°CWB; zunanja temp. 35°CDB, 24°CWB | (2) - Letna poraba energije: na podlagi povprečne rabe 500 obratovalnih ur na leto pri polni obremenitvi (nominalni pogoji) | (2) - Hlajenje: notranja temp. 27°CDB, 19°CWB; zunanja temp. 35°CDB, 24°CWB | (2) - Letna poraba energije: na podlagi povprečne rabe 500 obratovalnih ur na leto pri polni obremenitvi (nominalni pogoji) | (2) - Hlajenje: notranja temp. 27°CDB, 19°CWB; zunanja temp. 35°CDB, 24°CWB | ||||
| (3) - Hlajenje: notranja temp. 27°CDB, 19°CWB; zunanja temp. 35°CDB, 24°CWB | (3) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB | (3) - Hlajenje: notranja temp. 27°CDB, 19°CWB; zunanja temp. 35°CDB, 24°CWB | (3) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB | (3) - Hlajenje: notranja temp. 27°CDB, 19°CWB; zunanja temp. 35°CDB, 24°CWB | (3) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB | ||||
| (4) - Hlajenje: Notranja temperatura 27° CDB, 19° CWB; zunanja temperatura 35° CDB; 24° CWB | (4) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB | (4) - Hlajenje: Notranja temperatura 27° CDB, 19° CWB; zunanja temperatura 35° CDB; 24° CWB | (4) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB | (4) - Hlajenje: Notranja temperatura 27° CDB, 19° CWB; zunanja temperatura 35° CDB; 24° CWB | (4) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB | ||||
| (5) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB | (5) - 220V | (5) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB | (5) - 220V | (5) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB | (5) - 220V | ||||
| (6) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB | (6) - 230V | (6) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB | (6) - 230V | (6) - Ogrevanje: Notranja temperatura 20° CDB; zunanja temperatura 7° CDB, 6° CWB | (6) - 230V | ||||
| (7) - 220V | (7) - 240V | (7) - 220V | (7) - 240V | (7) - 220V | (7) - 240V | ||||
| (8) - 230V | (8) - Ob priklopu na večsistemsko zunanjo enoto glejte specifikacije za multi zunanjo enoto, ki naj se priklopi. | (8) - 230V | (8) - Ob priklopu na večsistemsko zunanjo enoto glejte specifikacije za multi zunanjo enoto, ki naj se priklopi. | (8) - 230V | (8) - Ob priklopu na večsistemsko zunanjo enoto glejte specifikacije za multi zunanjo enoto, ki naj se priklopi. | ||||
| (9) - 240V | (9) - Nom. učink.: hlajenje pri 35°/27° nom. obrem., gretje pri 7°/20° nom. obrem. | (9) - 240V | (9) - Nom. učink.: hlajenje pri 35°/27° nom. obrem., gretje pri 7°/20° nom. obrem. | (9) - 240V | (9) - Nom. učink.: hlajenje pri 35°/27° nom. obrem., gretje pri 7°/20° nom. obrem. | ||||
| (10) - Ob priklopu na večsistemsko zunanjo enoto glejte specifikacije za multi zunanjo enoto, ki naj se priklopi. | (10) - Ob priklopu na večsistemsko zunanjo enoto glejte specifikacije za multi zunanjo enoto, ki naj se priklopi. | (10) - Ob priklopu na večsistemsko zunanjo enoto glejte specifikacije za multi zunanjo enoto, ki naj se priklopi. | |||||||
| (11) - Nom. učink.: hlajenje pri 35°/27° nom. obrem., gretje pri 7°/20° nom. obrem. | (11) - Nom. učink.: hlajenje pri 35°/27° nom. obrem., gretje pri 7°/20° nom. obrem. | (11) - Nom. učink.: hlajenje pri 35°/27° nom. obrem., gretje pri 7°/20° nom. obrem. | |||||||